DIGITAL LINK MEASURING INSTRUMENTS
172 For product ordering information, see pages 4 –10
PORTABLE 2.5G/10G ANALYZER
MP1580A
For 2.5G/10G Jitter/Wander Measurements
NN
NN
EE
EE
WW
WW
The MP1580A is a unique and powerful solution for analyzing jitter
at the standard OC-48/192 or STM-16/64 bit rates. It can measure
jitter of 2.5G/10G electrical interfaces (clock signal) with a simple
operation. In addition, when used in combination with the MP1570A
SONET/SDH/PDH/ATM Analyzer, evaluation of jitter characteristics
in digital transmission lines, systems and devices, such as — jitter
tolerance, jitter transfer, jitter generation, etc., can be performed
easily.
Functions
Complies with the latest ITU-T O.172 and Bellcore GR-1377
standards
The MP1580A conforms to both the OC-192/STM-64 jitter measure-
ment standards and supports required jitter modulation amplitude of
4000 UIp-p and 80 MHz jitter bandwidth.
Supports 10 GHz wander measurement according to the latest
ITU-T G.813 standard (option)
The MP1580A can generate and measure various types of wander.
It can generate wander in the frequency range of 10 µHz to 10 Hz at
400,000 UIp-p max. In addition, MTIE/TDEV can be measured in
real-time using an external PC and optional application software
(MX150002A).
Single cabinet support for both 2.5G and 10G jitter/wander
measurements
Just one MP1580A is required for 2.5G and 10G jitter generation and
analysis. When combined with the MP1570A and MU150000A, jitter
can be added to SONET/SDH signals and measured.
Differences from existing instrument (MP1777A)
Anritsu launched the MP1777A 10 GHz Jitter Analyzer in February
of 1998, as a jitter measurement solution for OC-192/STM-64
(9953M). The new MP1580A Portable 2.5G/10G Jitter Analyzer is
providing more convenience in measurement without the need for
ancillary equipment (network analyzer, external E/O-O/E converter).
Anritsu has also developed a Wide Band O/E Converter
(MU150017A/B) for the MP1570A to support jitter measurement of
80 MHz at 9953.28 Mbit/s as required by ITU-T standard in conjunc-
tion with the MP1580A. Although it uses two cabinets, the compact
size makes the system ideal for R&D, manufacturing, installation and
maintenance. In addition, the MP1570A can be controlled from the
MP1580A for performing automatic measurements, such as Jitter
Tolerance and Jitter Transfer.
Application
Output jitter measurement
The MP1580A can easily measure the jitter clock signal (electrical in-
terface only) by just inputting the output clock of DUT directly.
Optical signals can be measured easily by combining the MP1580A
with the MP1570A, MU150000A, MU150001A and MU150017A/B.
Jitter tolerance measurement
When the MP1580A is used with the MP1570A (send/receive jittered
clock), jitter tolerance tests can be performed on OC-192/STM-64
and OC-48/STM-16 signals of electrical and optical interfaces.