http://www.anritsu.com 183
DIGITAL LINK MEASURING INSTRUMENTS
2
Automatic evaluation and measurement of AAL type
for 1023 channels
Specifications
•
MP1220B ATM Quality Analyzer
Display 10.4 inch TFT color LCD with touch panel (analog resistive membrane)
Memory storage 3.5 inch floppy disk drive (1.44 MB/720 KB) and hard disk drive (≥500 MB)
Buzzer Alarm, error
RS-232C (D-sub 9-pin), printer (Centronics, D-sub, 25-pin), keyboard (PS/2, mini-DIN, 6-pin), mouse (PS/2, mini-DIN, 6-pin), VGA
External interface
(analog RGB, D-sub, 15-pin)
Slots 6 (two channels max.)
EN55011: 1991, Group 1, Class A
EMC EN50082-1: 1992
Harmonic current emissions; EN61000-3-2: 1995, Class D
Safety EN61010-1: 1993 (Installation Category ΙΙ, Pollution Degree ΙΙ)
Dimensions and mass 284 (W) x 221.5 (H) x 365 (D) mm, ≤12 kg (excluding units)
Power supply 100 to 120/200 to 240 Vac (autoswitching), 50 to 60 Hz, ≤300 VA
Operating range Operating: 5˚ to 50˚C (excluding FDD), Storage: –20˚ to 60˚C
Bit rate 51.84, 155.52, 622.08 Mbps
Frames SDH/SONET
Connector: FC (replaceable), 1.31 µm band (SM)
Clock: Internal (±10 ppm), external, receive
Output signal Level: –15 to –8 dBm
Code: NRZ
Optical safety: IEC825-1 Class 1, 21CFR1040.10 Class
Ι
Connector: FC (replaceable), 1.31 µm band (SM)
Frequency range: ±100 ppm
Input signal
Level: –34 to –8 dBm (51.84 Mbps, 155.52 Mbps), –28 to –8 dBm (622.08 Mbps)
Code: NRZ
SOH/POH setting, SOH/POH monitoring, path trace, empty cell setting, cell scramble (de-scramble) on/off, coset on/off, HEC error
correction on/off
Error addition: Bit, B1, B2, B3, FEBE-L, FEBE-P, cell
Functions
Alarm addition: LOS, LOF, AIS-L, RDI-L, AIS-P, RDI-P, LCD
Error measurement: B1, B2, B3, MS-REI (FEBE-L), HP-REI (FEBE-P), HEC corrected cells, HEC uncorrected cells
Alarm measurement: LOS, OOF, LOF, MS-AIS (AIS-L), MS-RDI (RDI-L), AU-AIS (AIS-P), HP-RDI (RDI-P), AU-LOP (LOP-P), LCD
Pointers: Monitor, ±justification, NDF
Auxiliary output: Receive clock output, trigger output
Bit rate 155.52 Mbps
Frames SDH/SONET
Connector
Optical: SC 1.31 µm (SM); Electrical: BNC 75 Ω
Clock: Internal (±10 ppm), external, receive
Output signal
Optical level: –15 to –8 dBm
Electrical level: 1 ±0.1 Vp-p (CMI)
Code
Optical: NRZ, Electrical: CMI
Optical safety: IEC825-1 Class 1, 21CFR1040.10 Class
Ι
•
MU120001A STM-4/OC-12 Unit
•
MU120002A STM-1/OC-3 Unit
Continued on next page