Anritsu MG3642A Manual de usuario Pagina 79

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 212
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 78
SECTION 4 OPERATING INSTRUCTIONS
4-39
Sweep Auxiliary
Output Connector
MG3641A/MG3642A rear panel
4.10.3 Sweep Auxiliary Outputs
While the signal generator performs sweep, it outputs signals that are synchronized to the sweep through the four
connectors located on the rear panel, as follows:
(1) X Out
Outputs sawtooth waves that are at 0 V at the sweep start point, and at +10 V at the sweep end point.
(2) Z Out
Outputs "H"-level TTL signals while it continues with sweep.
(3) Blanking Out
Outputs "H"-level TTL signals every sweep step, from the time when hardware setting is completed, till the next
step setting begins
(4) Marker Out
Outputs "H"-level TTL signals when the actual sweep matches the marker point which was set in the "Sweep
Parameter" menu.
Vista de pagina 78
1 2 ... 74 75 76 77 78 79 80 81 82 83 84 ... 211 212

Comentarios a estos manuales

Sin comentarios