SECTION 6 GPIB
6-31
:FREQuency:SWEep:TIME <Numeric> <Time term>
Function Sets the sweep time for a frequency sweep.
Parameter <Numeric> = 0.1 ms to 600 s
Unit <Time term>
Restriction None
:FREQuency:SWEep:TIME?
Function Reads out the sweep time for a frequency sweep.
Response Sweep time for a frequency sweep
Restriction None
:FREQuency:SWEep:MARKer <Numeric> <Freq term>
Function Sets the marker frequency for a sweep.
Parameter <Numeric> = 0.01 Hz to 1040 MHz (MG3641A)
0.01 Hz to 2080 MHz (MG3642A)
Unit <Freq term>
Restriction None
:FREQuency:SWEep:MARKer?
Function Reads out the marker frequency for a sweep.
Response Marker frequency for a sweep
Restriction None
:FREQuency:SWEep:PATTern
Function Sets the frequency sweep pattern.
Parameter <Character> = SIZE
NO
LOG
Unit <Non term>
Restriction None
:FREQuency:SWEep:PATTern?
Function Reads out the frequency sweep pattern.
Response Frequency sweep pattern = SIZE
NO
LOG
Restriction None
:FREQuency:SWEep:TYPE <Numeric>
Function Sets the frequency sweep type.
Parameter <Numeric> = 0 (START-STOP)
1 (CENTER-SPAN)
Unit <Non term>
Restriction None
:FREQuency:SWEep:TYPE?
Function Reads out the frequency sweep type.
Response Frequency sweep type = 0 (START-STOP)
1 (CENTER-SPAN)
Restriction None