19. On the MG3692A Synthesized Signal
Source, adjust the output level so that
the M1 reading of Site Master Spectrum
Analyzer is –30 dBm at 40 MHz.
20. On the Site Master, press the
FREQ/DIST
key and then the CENTER soft key.
21. Enter
80 and press the MHz soft key to
set the center frequency to 80 MHz.
22. Press the MARKER key and the M1 soft
key.
23. Select the
EDIT soft key, then enter 80.
Press the
MHz soft key to set M1 to 80
MHz .
24. Record the amplitude of the signal at M1
80 MHz:
Second Harmonic Level @ 80 MHz =____dBm
25. Convert this measured value to dBc us
-
ing the following formula:
Input Related Spurious Response (dBc) =
[Second Harmonic Level @ 80 MHz] +
30 dBm = ___ dBc
Specifications for this measurement are –45
dBc with –30 dBm into the first mixer.
8. SPECTRUM ANALYZER RESIDUAL
SPURIOUS RESPONSE TEST
The following test can be used to verify the residual
spurious response of the Site Master Spectrum Ana
-
lyzer.
a. Equipment Required:
·
Anritsu 28N50-2 or SM/PL 50 ohm Ter
-
mination or equivalent
b. Procedure:
1. Connect the 50 ohm termination to the
Site Master RF Input.
2. On the Site Master, press and hold the
ESCAPE/CLEAR key, then press the
ON/OFF key to turn on the Site Master.
(This sets the instrument to the factory
preset state.)
NOTE
Before continuing, allow a 30-minute warm up
for the internal circuitry to stabilize.
3. On the Site Master, press the
MODE key.
Use the up/down arrow key to highlight
SPECTRUM ANALZYER and press ENTER
to select spectrum analyzer mode.
4. Press the
AMPLITUDE key and the REF
LEVEL
soft key.
5. Enter –75 and press the
ENTER key to set
the Reference Level to –75 dBm.
6. Press the SCALE soft key and enter 5,
then press ENTER.
7. Press the
SWEEP key.
8. Press the
RBW soft key and then the
MANUAL soft key. Use the Up/down arrow
key to select
10 kHz. Press ENTER to set
the resolution bandwidth to 10 kHz and
select
BACK.
9. Press the
VBW soft key and then the
MANUAL soft key. Use the Up/down arrow
key to select
100 Hz and press ENTER to
set the video bandwidth to 100 Hz.
10. Press the
FREQ/DIST key and the START
soft key.
11. Enter
500 and press the kHz soft key to
set the start frequency to 500 kHz.
12. Press the STOP soft key and enter 4, then
press the
MHz soft key to set the stop fre-
quency to 4 MHz.
13. Wait till one full sweep is complete.
14. Press the
MARKER key and then the M1
soft key.
15. Press the
ON/OFF soft key and then the
MARKER TO PEAK soft key.
16. Record the M1 amplitude reading and
verify whether it is less than or equal to
–90 dBm.
NOTE
If a spur with an amplitude larger than –90
dBm occurs, wait another full sweep and ob
-
serve whether the spur occurs at the same
point on the second sweep. If the spur does not
occur at the same point on the second sweep,
then the spur on the first sweep was not real.
17. Press the
SWEEP key.
18. Press the
VBW soft key and then the
MANUAL soft key. Use the Up/down arrow
key to select
3 kHz and press ENTER to set
the video bandwidth to 3 kHz.
Site Master S114C/S332C MM 5