8
Various Analysis Functions
The internal optical power meter and frequency counter allows
the user to measure optical power and frequency during error
and alarm measurement. (Photo A)
The MP1570A can capture any SOH or POH (1 byte), K1/ K2
byte, or H1/H2 byte in 1023 frames to analyze errors and
alarms, and check APS operation. (Photo B)
Measured errors and alarms can be displayed as a graph with
a time scale in 1 second, 1 minute, 15 minutes, or 60 minutes.
(Photo C)
C: Error/alarm
Pointer Value Monitoring
Changes in pointer value can be displayed as a graph with
values updated in real time.
Pointer monitor
A: Optical power meter
B: Overhead capture