Site Master is the preferred cable and antenna analyzer of wireless providers, contractors and installers.
Cable and Antenna Analyzer
The cable and antenna analyzer tool provides for return loss/SWR, cable loss, and distance-to-fault measurements.
This enables quick evaluations of the health and status of transmission lines and antenna systems, and speeds the
benchmarking of new cell site installations at the time of commissioning.
Spectrum Analyzer (S332D Models)
The spectrum analyzer enables field technicians to analyze and identify over-the-air interference and transmitter
characteristics easily, without having to lug a separate instrument.
Power Meter (Option 29)
The power meter tool performs accurate power measurements, reducing coverage holes and interference.
T1 and E1 Analyzer (Option 50 on S331D Models only)
The Site Master performs full T1/E1 functional tests, simplifying the task of determining if the source of
problems is on the wireline or the wireless side.
Powerful PC based Data Management and Analysis Software
A comprehensive data management and analysis software suite comes with every Site Master unit, providing users
with a simple and easy method of managing, archiving, and analyzing system performance, trends, and the general
health of monitored base stations. The Handheld Software Tools also provide a professional report generator, for
those times when recorded data must be communicated.
The Handheld Software Tools are Windows 95/98/NT4/2000/ME/XP compatible,
and supports long alpha-numeric file names for descriptive data labeling
Stores an unlimited number of data traces for comparison of historical performance
measurements, easing the task of trend analysis
Transfer data traces between the Site Master and the PC with a single menu selection
Has the ability to convert Return Loss measurements to Distance-To-Fault measurements
Handheld Software Tools has DTF and Smith Chart analysis capabilities
Color LCD Display (Option 3)
640x480 color STN display for crisp display/trace representation in indoor lighting conditions.
Snap-in Field
replaceable battery
location
RS-232 Interface
Transfer stored data to and
from a personal computer (PC)
or download to a printer via a
serial cable for further analysis.
Use PC to automatically control
and collect data in the field.
Large High
Resolution Display
Standard VGA (640x480) or
optional color monitor STN
(640x480) display featuring
contrast and variable back-
lighting capability. Easy viewing
under a variety of conditions.
Rugged & Reliable
Chassis Design
Ruggedized, lightweight,
compact, high-impact housing
is designed to withstand
repeated drops and rough
handling. Weather resistant
seals and rubber membrane
keypad protect unit from dirt
and moisture.
Function Keys
Four dedicated function keys simplify
measurement tasks.
External DC
Power Port
Multilingual User Interface
Multi-language user interface
features on-screen menus and
messages in 6 different
languages: Chinese, English,
French, German, Japanese,
Spanish.
Save & Recall Display
Up to 200 memory
locations. Alphanumeric
data labeling and
automatic time/date
stamp simplifies data
management.
Limits
Create simple pass/fail
measurements with a single
limit line, upper and/or lower
mask limit lines.
Markers
6 markers for more
comprehensive
measurements.
Save & Recall Setup
Setups for fast
repeatable testing:
S332D Models - 20
S331D Models - 25
T1/E1
Receive & Transmit Port
(S331D Models with Option 50)
Ext Trig & Ext Ref In Cable & Antenna
Analyzer Port
Spectrum Analyzer
& Power Meter Port
Soft Keys
Intuitive soft key menu
and user interface.
Cost Savings and Quality Improvement
Wireless market competition requires operators to reduce per site maintenance expense.
Site Master’s Frequency Domain Reflectometry (FDR) techniques break away from the
traditional fix-after-failure maintenance process by finding small, hard to identify
problems before major failures occur.
Sixty to eighty percent of a typical cell site’s problems are caused by problematic cables,
connectors and antennas. When cables/antennas are contaminated with moisture or are
damaged/mis-positioned during storms, Site Master identifies the problem quickly.
Antenna degradation reduces the cell coverage pattern and can cause dropped calls. Site
Master can pinpoint the antenna problem from ground level in a few seconds so climbing
to the antenna tower becomes unnecessary.
A poorly installed weather seal will corrode connectors and, if undetected, will eventually
damage an expensive coaxial cable. Site Master has the sensitivity to identify the connector
problem before the cable is damaged. Distance-To-Fault provides the clearest indication
of troubled areas.
Test / Capability Benefits
25 MHz to 4000 MHz Covers all cell site frequency ranges without
additional plug-ins or instruments
Built-in calibration intelligence Ensures accurate and proper calibration
FlexCal
Allows troubleshooting cable and antenna systems
without multiple calibrations and calibration setups
Superior immunity to interference Accurate and repeatable measurements in
RF-noisy environments
130, 259, and 517 data points Optimizes distance measurement
resolution and fault locations
<500 msec per sweep Enables easier identification of
intermittent, real-time problems
Built-in average cable loss No more guess work or need to calculate a measured
value computation cable loss value
Built-in worldwide signal standards Common language for cell technicians that eliminates
the need to remember and manually input start and
stop frequencies
Test / Capability Benefits
100 kHz to 3000 MHz Covers all mobile system frequencies without
requiring additional plug-ins or instruments
Built-in worldwide signal standards Common language to cell technicians and eliminates
and frequency channels the need to perform channel-to-frequency translation
–135 dBm amplitude sensitivity Ability to detect low level signals
Interference Analysis measurement Analyzes a received signal and displays signal standard
and bandwidth to understand interference problems
Carrier-to-Interference Ratio (C/I) Ensures received signal quality in the
measurement presence of interference
One-button measurements: Quicker, convenient measurements
Field Strength, Occupied Bandwidth
Channel Power, Adjacent Channel
Power Ratio, Interference Analysis and
Carrier-to-Interference Ratio
Test / Capability Benefits
Requires no additional power sensors No additional parts to carry to the field
Test / Capability Benefits
Full function T1 and E1 tests No need to purchase or carry separate
wireline testers
Histogram display Provide continuous monitoring or overnight
monitoring of wireline health
Site Master
revolutionizes
Cable and
Antenna
Sweeping in
the Wireless
Industry.