Adjacent Channel Power Ratio
Another common transmitter measurement is that of adjacent channel leakage power. This
is defined as the ratio of the amount of leakage power in an adjacent channel to the total
transmitted power in the main channel. This measurement can be used to replace the tradi-
tional two-tone intermodulation distortion (IMD) test for system non-linear behavior.
The result of an ACPR measurement can be expressed either as a power ratio or a power
density. In order to calculate the upper and lower adjacent channel values, the Site Master
requires the specification of four parameters:
r
Main Channel Center Frequency
r
Measurement Channel Bandwidth
r
Adjacent Channel Bandwidth
r
Channel Spacing
GSM Adjacent Channel Power Measurement
Required Equipment
r
Site Master S114C/S332C
r
30 dB, 50 watt, Bi-Directional, DC – 18 GHz, N(m) – N(f), Attenuator,
Anritsu 42N50A-30
r
Test Port extension cable, Anritsu 15NNF50 – 1.5C
Procedure
Step 1. Reset the Site Master to the factory default settings if a known starting state is
desired.
If the unit is off, hold down the ESC/CLEAR key while pressing the ON/OFF
key.
If the unit is already on, press the RECALL SETUP key on the data keypad.
When the key is pressed, a Recall Trace selection box appears on the display.
Select setup location 0 to recall the factory preset state.
Step 2. Using the test port extension cable and 30 dB attenuator, connect the signal
source to the input of the attenuator, and connect the output of the attenuator to
the
RF In test port of the Site Master.
Step 3.
Press the AMPLITUDE key and select the
REF LEVEL soft key to set the refer-
ence level to 0 dBm.
Step 4. Press the
ATTEN soft key and set the attenuation to AUTO.
Step 5.
Press the SWEEP key and select the
RBW and VBW soft keys to set the resolu-
tion bandwidth to 1 MHz and the video bandwidth to AUTO.
Step 6. Press the
MAX HOLD soft key to set max hold to ON as indicated in the lower
left of the display.
Step 7. Press the
MEASURE soft key and press the ACPR soft key.
Step 8. Select the
CENTER FREQ soft key, and enter 945.7 MHz or another desired
center frequency.