Set Spectrum Analyzer Peak Hold – Control Byte #105 (69h)
Description: Sets the max hold and min hold settings on the Spectrum Analyzer.
Bytes to Follow: 1 byte
1) Peak Hold State
00h – Peak Hold Off
01h – Max Hold On
02h – Min Hold On
Site Master Returns: 1 byte
1) 255 (FFh) Operation Complete Byte
224 (E0h) Parameter Error: Invalid state
238 (EEh) Time Out Error
Set Spectrum Analyzer Resolution Bandwidth – Control Byte #106 (6Ah)
NOTE: This command exists for backward compatibility with the S33xC models. Features new to the
S33xD models are not available here. To access the new features use Control Byte #141 (8Dh).
Description: Sets the resolution BW frequency for the Spectrum Analyzer.
Bytes to Follow: 1 byte
1) Resolution Bandwidth Index
00h – 10 kHz BW
01h – 30 kHz BW
02h – 100 kHz BW
03h – 1 MHz BW
Site Master Returns: 1 byte
1) 255 (FFh) Operation Complete Byte
224 (E0h) Parameter Error: Invalid RBW Index
238 (EEh) Time Out Error
Set Spectrum Analyzer Video Bandwidth – Control Byte #107 (6Bh)
NOTE: This command exists for backward compatibility with the S33xC models. Features new to the
S33xD models are not available here. To access the new features use Control Byte #142 (8Eh).
Description: Sets the video BW frequency for the Spectrum Analyzer.
Bytes to Follow: 1 byte
1) Video Bandwidth Index
00h – 100 Hz BW
01h – 300 Hz BW
02h – 1 kHz BW
03h – 3 kHz BW
04h – 10 kHz BW
05h – 30 kHz BW
06h – 100 kHz BW
07h – 300 kHz BW
Site Master Returns: 1 byte