Technical Data Sheet
Power Meters and Power Sensors
ML2430A CW Power Meter
ML2480B Wideband Power Meter
ML2490A Pulse Power Meter
MA2400A/D & MA24000A Power Sensors
Anritsu Power Meters and Power Sensors: Accurate, Fast, and Affordable.
Vista de pagina 0
1 2 3 4 5 6 ... 11 12

Indice de contenidos

Pagina 1 - ML2490A Pulse Power Meter

Technical Data SheetPower Meters and Power SensorsML2430A CW Power Meter ML2480B Wideband Power Meter ML2490A Pulse Power Meter MA2400A/D & MA240

Pagina 2 - Introduction

10Measurement AccuracyPower measurement accuracy can be split into several parts. The table below shows how the measurement uncertainty is composed fo

Pagina 3 - Power Meter Specifications

11Ordering InformationPower Meter ModelsML2495A Pulse Power Meter, Single InputML2496A Pulse Power Meter, Dual InputML2487B Wideband Power Meter, S

Pagina 4

Technical Data Sheet No. 11410-00423, Rev. D Printed in United States 2009-02©2009 Anritsu Company. All Rights Reserved.® Anritsu All trademarks ar

Pagina 5

2IntroductionAnritsu offers the world’s most comprehensive range of power meters. The ML2490A series has the performance required for narrow fast risi

Pagina 6 - Save/Recall

3Power Meter SpecificationsML2430A Series ML2480B Series ML2490A Series CommentsML2437A ML2438A ML2487B ML2488B ML2495A ML2496ASignal Inputs 1 2 1 2 1

Pagina 7

4ML2430A Series ML2480B Series ML2490A Series CommentsML2437A ML2438A ML2487B ML2488B ML2495A ML2496AOperation2 2 (CW or Pulse/Modulated measurement m

Pagina 8 - ±100 dB

5ML2430A Series ML2480B Series ML2490A Series CommentsML2437A ML2438A ML2487B ML2488B ML2495A ML2496AAveragingAuto (Moving), Manual (Moving, Repeat) T

Pagina 9

6ML2430A Series ML2480B Series ML2490A Series CommentsML2437A ML2438A ML2487B ML2488B ML2495A ML2496ATriggeringN/A ±2 ns for pre and post trigger (Tri

Pagina 10 - Measurement Accuracy

7Power Meter SpecificationsML2430A Series ML2480B Series ML2490A Series CommentsReference Calibrator1 mW Power±1.2% per year, ±0.9% RSSPower accuracy

Pagina 11 - Ordering Information

8USB Power Sensor SpecificationsMA24106A Power SensorFrequency range 50 MHz to 6 GHzDynamic range –40 dBm to +23 dBmInput return loss >26 dB (50 MH

Pagina 12 - Power Sensor Models

9Power Sensor Specifications continued Frequency Range CW Dynamic Range (dBm) SWR Rise Time1 (ms) Sensor Linearity7RF Connector2 Standard Diode Se

Comentarios a estos manuales